logo
Found 939 results for "

data center ups

"
Qualité 6KVA 7.5KVA 10KVA 3 phases industrielles UPS numérique alimentation en ligne UPS Visench OEM géant Elite usine

6KVA 7.5KVA 10KVA 3 phases industrielles UPS numérique alimentation en ligne UPS Visench OEM géant Elite

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité Visench 6KVA 6000W 6KW Pure Sine Wave en ligne UPS industriel Pour la sécurité / surveillance / alarme usine

Visench 6KVA 6000W 6KW Pure Sine Wave en ligne UPS industriel Pour la sécurité / surveillance / alarme

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité Visench Giant Elite 3p1p 6KVA 6000W 6KW 3Phase UPS en ligne pour la sécurité / surveillance / alarme usine

Visench Giant Elite 3p1p 6KVA 6000W 6KW 3Phase UPS en ligne pour la sécurité / surveillance / alarme

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité Visench Giant iNDll 33-10k 10KVA 10KW 10000VA 10000W UPS en ligne Pour ordinateur / réseau usine

Visench Giant iNDll 33-10k 10KVA 10KW 10000VA 10000W UPS en ligne Pour ordinateur / réseau

Product nameGiant iND IIRated Capacity10kva-160kvaRectifier Type6 pulse / 12 pulsePower Factor0.9, customized up to 1.0Input Voltage380VACI400VACI415VACFrequency50Hz/60Hz + 10%Output Voltage380VACI400VACI415VACTVSS40KAFrequency50Hz/60Hz± 1%Altitude1000mSafetyIEC62040-1-2017Battery Voltage384 VDC (Adjustable)Cold StartYesDry Contacts5 outputs and 4 inputsIP ProtectionIP31 (default), IP42 (optional)Operating Temperature0~ 40°CSize(mm)800 x 800 x 1800Weight(Kgs)349/385/427/508

Qualité 10KVA 6KVA 3KVA Pure Sinewave 360v/380v/400v/415v UPS en ligne Pour les télécommunications usine

10KVA 6KVA 3KVA Pure Sinewave 360v/380v/400v/415v UPS en ligne Pour les télécommunications

Product nameArena 3U Online UPSPHASE3 phase in/3 phase outInput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Power Factor≥0.99 @100%loadOutput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Current Crest Ratio3:1 (max.)WaveformPure SinewaveOperating Humidity0-95%RH @0-40°℃(non-condensing)Dimension,DxWxH(mm)678x418x129 [3U]Net Weight (kgs)20.5/17.6/21Frequency Range46~54Hz or 56~64HzHarmonic Distortion≤2%THD (Linear Load);≤3%THD (Non-linear Load)Inverter to BypasszeroCAPAC

Qualité Visench Giant Elite 3p1p 7.5KVA 7500W 7.5KW 3-phase industrielle Pure Sine Wave en ligne UPS usine

Visench Giant Elite 3p1p 7.5KVA 7500W 7.5KW 3-phase industrielle Pure Sine Wave en ligne UPS

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité Visench Giant Elite 10KVA 10KW 10000W 3Phase Pure Sine Wave UPS en ligne pour le secteur industriel usine

Visench Giant Elite 10KVA 10KW 10000W 3Phase Pure Sine Wave UPS en ligne pour le secteur industriel

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité Visench Giant Elite 6KW 7.5KW 10KW 3Phase Industrial 220V/Pure Sine Wave UPS en ligne Pour les télécommunications usine

Visench Giant Elite 6KW 7.5KW 10KW 3Phase Industrial 220V/Pure Sine Wave UPS en ligne Pour les télécommunications

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp

Qualité 208VAC/220VAC/230VAC Visench géant Elite 6000W 7500W 10000W 3phase tour industrielle UPS usine

208VAC/220VAC/230VAC Visench géant Elite 6000W 7500W 10000W 3phase tour industrielle UPS

Product nameGiant Elite 3p1pRated Capacity6kva-10kvaVoltage Regulation± 1%Input Voltage3x360VAC1380VAC1400VAC(3Ph+N+G)Frequency40 Hz~ 55 Hz @ 50Hz system ; 56 Hz~ 64 Hz @ 60Hz systemOutput Voltage208VAC1220VAC/230VAC (Se lectable)WaveformPure SinewaveBattery Type12V/ 9AhPHASE3-phase in / 1-phase outHarmonic Distortion≤ 3 % THD (Linear Load); ≤ 5 % THD (Non-inear Load)Current Crest Ratio3:01Battery Mode92.00%Frequency Range50 Hz ± 0.1 Hz or 60Hz± 0.1 HZInverter to BypassZeroOp